{"id":28156,"date":"2025-05-06T11:46:07","date_gmt":"2025-05-06T08:46:07","guid":{"rendered":"https:\/\/www.mitera.gr\/?page_id=28156"},"modified":"2025-06-26T22:02:57","modified_gmt":"2025-06-26T19:02:57","slug":"exoplismos","status":"publish","type":"page","link":"https:\/\/www.mitera.gr\/en\/exoplismos\/","title":{"rendered":"\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1"},"content":{"rendered":"<div class=\"exoplismos-wrapper\">            <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/\u03a6\u03a9\u03a4\u039f\u0393\u03a1\u0391\u03a6\u0399\u0391-\u03a3\u03a5\u03a3\u039a\u0395\u03a5\u0397\u03a3.jpg\" \n                         alt=\"OPTOS SILVERSTONE SS OCT\"\n                         loading=\"lazy\">\n                                \n                <h3>OPTOS SILVERSTONE SS OCT<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">OPTOS Silverstone, the most powerful tool yet for examining the retina, is the only ultra-widefield imaging device with integrated swept-source...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p><strong><u>OPTOS Silverstone<\/u><\/strong><u>,<\/u> <strong>the most powerful tool yet for examining the retina<\/strong>, is the<strong> only ultra-widefield imaging device with integrated swept-source OCT<\/strong>.<\/p>\n<p>OPTOS\u00a0<em>Silverstone<\/em>\u00a0produces a 200\u00b0 single-capture retinal image of unrivaled clarity in less than \u00bd second and enables\u00a0<strong>opto<\/strong><strong>map-guided\u00a0OCT<\/strong> scanning across the retina and into the far periphery.<\/p>\n<p>Routine optomap use <strong>enhances pathology detection, disease management, and clinic flow<\/strong>.<\/p>\n<p>Now, with Silverstone, examination of the retina from vitreous through the choroidal-scleral interface is faster and easier than ever.<\/p>\n<p>OPTOS Silverstone SS OCT, the most powerful tool for examining the retina in patients with ocular Malignancies.<\/p>\n<p><strong>The\u00a0Ocular Oncology Centre of MITERA Hospital is\u00a0<u>The only Ophthalmic center\u00a0<\/u>in Greece with this Equipment<\/strong><\/p>\n<p>See more<\/p>\n<p><strong><em><u>OPTOS Silverstone<\/u><\/em><\/strong><strong><u>\u00a0offers the following benefits:<\/u><\/strong><\/p>\n<ul>\n<li>UWF with integrated swept-source OCT, facilitates detailed examination of the retina-vitreous to sclera<\/li>\n<li>UWF-guided, swept-source OCT, images pathology anywhere on the\u00a0optomap<\/li>\n<li>1050 nm OCT light source, provides deeper tissue penetration for clear, detailed choroidal imaging<\/li>\n<li>3-in-1 Color Depth Imaging<sup>TM<\/sup>\u00a0provides important clinical data from the retinal surface through the choroid<\/li>\n<\/ul>\n<p><strong><u>Image Views<\/u><\/strong><\/p>\n<ul>\n<li>Standard:\u00a0 200\u2070 Single Capture<\/li>\n<li>Auto-montage: \u00a0Up to 220\u2070\u00a0(not available for fa or icg)<\/li>\n<li>Central Pole: \u00a0Detailed view of the macula<\/li>\n<li>Stereo: Image pairing for optic disc and retinal evaluation<\/li>\n<li>OCT: Up to 23mm line scan and swept-source functionality<\/li>\n<\/ul>\n<p><strong><u>opto<\/u><\/strong><strong><u>map\u00a0Image Modalities<\/u><\/strong><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Color rg<\/li>\n<li>Sensory Red-free<\/li>\n<li>Choroidal<\/li>\n<li>Autofluorescence<\/li>\n<li>Fluorescein angiography<\/li>\n<li>Indocyanine green angiography<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>OCT<\/li>\n<\/ul>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/\u03a6\u03a9\u03a4\u039f\u0393\u03a1\u0391\u03a6\u0399\u0391-\u03a3\u03a5\u03a3\u039a\u0395\u03a5\u0397\u03a3-1.jpg\" \n                         alt=\"OPTOS SILVERSTONE SS OCT FLUORESCEIN ANGIOGRAPHY\"\n                         loading=\"lazy\">\n                                \n                <h3>OPTOS SILVERSTONE SS OCT FLUORESCEIN ANGIOGRAPHY<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">OPTOS\u00a0Silverstone\u00a0Fluorescein Angiography ultra-widefield, ultra-high resolution angiography, enables a simultaneous pole-to-periphery view of the retina of the eye. This supports practitioners...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>OPTOS\u00a0<em>Silverstone\u00a0<\/em>Fluorescein Angiography ultra-widefield, ultra-high resolution angiography, enables a simultaneous pole-to-periphery view of the retina of the eye. This supports practitioners in diagnosing ocular pathology that may first present in the periphery of the retina, resulting in better patient outcomes.<\/p>\n<p><strong>The\u00a0Ocular Oncology Centre of MITERA Hospital is\u00a0<u>The only Ophthalmic center\u00a0<\/u>in Greece with this Equipment<\/strong><\/p>\n<p>This allows the entire retinal vasculature to be imaged during the dye transit by a non-contact method<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/\u03a6\u03a9\u03a4\u039f\u0393\u03a1\u0391\u03a6\u0399\u0391-\u03a3\u03a5\u03a3\u039a\u0395\u03a5\u0397\u03a3-2.jpg\" \n                         alt=\"OPTOS SILVERSTONE SS OCT INDOCYANINE GREEN ANGIOGRAPHY\"\n                         loading=\"lazy\">\n                                \n                <h3>OPTOS SILVERSTONE SS OCT INDOCYANINE GREEN ANGIOGRAPHY<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">OPTOS\u00a0Silverstone\u00a0Indocyanine Green Angiography (ICG) ultra-widefield, ultra-high resolution angiography, enables a simultaneous pole-to-periphery view of the retina of the eye. This...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>OPTOS\u00a0<em>Silverstone\u00a0<\/em>Indocyanine Green Angiography (ICG) ultra-widefield, ultra-high resolution angiography, enables a simultaneous pole-to-periphery view of the retina of the eye. This allows the entire retinal vasculature to be imaged during the dye transit by a non-contact method.<\/p>\n<p>It can yield additional information helpful in differentiating amongst choroidal tumors allowing more accurate treatment planning and follow-up.<\/p>\n<p><strong>The\u00a0Ocular Oncology Centre of MITERA Hospital is\u00a0<u>the only Ophthalmic center\u00a0<\/u>in Greece with this Equipment<\/strong><\/p>\n<p>This supports practitioners in diagnosing ocular pathology that may first present in the periphery of the retina, resulting in better patient outcomes.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/retcam-envision.jpg\" \n                         alt=\"RETCAM ENVISION\"\n                         loading=\"lazy\">\n                                \n                <h3>RETCAM ENVISION<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">RetCam Envision sets the standard in pediatric ocular imaging, delivering brilliant images and very important diagnostic test in children with...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p><strong>RetCam Envision sets the standard in pediatric ocular imaging, delivering brilliant images and very important diagnostic test in children with retinoblastoma. Absolutely necessary for ocular oncology specialty. RetCam makes pediatric ocular imaging easy, and sets a new standard in the field. <\/strong><\/p>\n<p>Enhanced illumination with an ultra-wide field of view makes RetCam Envision <strong>the leader in image quality<\/strong>.<\/p>\n<p><strong>RetCam Envision\u2019s fluorescein angiography (FA)<\/strong> option is a diagnostic aid to examine the circulation of the retinal blood vessels and assist with the detection of anatomical abnormalities<\/p>\n<p><strong>The\u00a0Ocular Oncology Centre of MITERA Hospital is\u00a0<u>The only Ophthalmic center\u00a0<\/u>in Greece with this Equipment<\/strong><\/p>\n<p>With Light Shaping Technology patent users experience a greater visualization with brilliant color images. These unique features result in images that provide a higher level of confidence for patient evaluations and consultations. Brilliant color images can be viewed in full-screen mode for <strong>maximum visualization of detail, enabling earlier detection of eye diseases and timely intervention<\/strong>.<\/p>\n<p>The RetCam Envision\u2019s lens portfolio, <strong>detachable portrait lens and detachable 130<\/strong><strong><sup>\u03bf<\/sup><\/strong> <strong>lens<\/strong>, provides the best partner for <strong>anterior and posterior imaging<\/strong>. Together with the Light Shaping Technology, lenses <strong>give focus across the entire 130\u00ba field of view, improved peripheral illumination, and better illumination of darkly pigmented retinas<\/strong>. Furthermore, lenses can be removed easily for <strong>cleaning and disinfecting<\/strong> with minimal downtime. It provides the ability to visualize the absence or presence of blood flow within the eye.<\/p>\n<p>&nbsp;<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/\u03a6\u03a9\u03a4\u039f\u0393\u03a1\u0391\u03a6\u0399\u0391-\u03a3\u03a5\u03a3\u039a\u0395\u03a5\u0397\u03a3_retcam.jpg\" \n                         alt=\"RETCAM ENVISION FLUORESCEIN ANGIOGRAPHY\"\n                         loading=\"lazy\">\n                                \n                <h3>RETCAM ENVISION FLUORESCEIN ANGIOGRAPHY<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">RetCam Envision\u2019s fluorescein angiography\u00a0option is a\u00a0diagnostic aid to examine the circulation of the retinal blood vessels and assist\u00a0with the detection...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>RetCam Envision\u2019s fluorescein angiography\u00a0option is a\u00a0diagnostic aid to examine the circulation of the retinal blood vessels and assist\u00a0with the detection of anatomical abnormalities. An essential test in retinoblastoma patients defining the extent of the disease and distinguishing this tumour from other pediatric ocular condition.<\/p>\n<p><strong>The Ocular Oncology Centre of MITERA Hospital is\u00a0<\/strong><strong><u>The only Ophthalmic center\u00a0<\/u><\/strong><strong>in Greece with this Equipment\u00a0<\/strong><\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/haag.jpg\" \n                         alt=\"HAAG-STREIT BX-900\"\n                         loading=\"lazy\">\n                                \n                <h3>HAAG-STREIT BX-900<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">World-wide famous, Swiss-made Haag-Streit Slit Lamp meets professional photography in the unique combination of BX-900. Making use of the excellent...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>World-wide famous, Swiss-made Haag-Streit Slit Lamp meets professional photography in the unique combination of BX-900.<\/p>\n<p>Making use of the excellent microscope optics and a DSLR camera, the user has the power to capture astonishing details of the Anterior Chamber and the Cornea pathologies and drastically contribute with diagnosing and treating them.<\/p>\n<p>The Haag-Streit BX-900 is a no-compromise slit lamp-imaging instrument designed an important diagnostic test in patients with suspicious lesions on the anterior segment of the eye.<\/p>\n<p><strong>The\u00a0Ocular Oncology Centre of MITERA Hospital is\u00a0<u>the only Ophthalmic center\u00a0<\/u>in Greece with this Equipment<\/strong><\/p>\n<p>The BX 900 slit lamp is a no-compromise slit lamp imaging instrument designed to assist ophthalmic healthcare providers.i<\/p>\n<p>Benefit from the best camera systems on the market. The Haag-Streit BX 900 slit lamp can be equipped with various professional camera systems thanks to its universal adapter, which is elegantly located above the slit lamp microscope.n<\/p>\n<p>&nbsp;<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/optical.jpg\" \n                         alt=\"OPTICAL COHERENCE TOMOGRAPHY (OCT) HAND-HELD LEICA ENVISU C2300\"\n                         loading=\"lazy\">\n                                \n                <h3>OPTICAL COHERENCE TOMOGRAPHY (OCT) HAND-HELD LEICA ENVISU C2300<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Envisu, is a hand-held OCT solution with an intended use to aid in the diagnosis of physiological and pathologic conditions...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Envisu, is a hand-held OCT solution with an intended use to aid in the diagnosis of physiological and pathologic conditions of the eye. It has an essential role in retinoblastoma management, particularly in tracking submillimeter tumors. It is vital in retinoblastoma care to confirm retinoblastoma recurrence, influencing the decision to provide further treatment, and establioshing the tumor response to therapy.<\/p>\n<p>Quickly capture and observe brilliant, high-resolution, and high-density optical coherence tomography (OCT) images where you need it.<\/p>\n<p>The gentle, non-contact Envisu C2300 system <strong>has a significant impact on pediatric ocular oncology, especially on retinoblastoma cases. <\/strong><\/p>\n<p>Permits <strong>precise tumor monitor for growth and detection of subclinical or invisible retinoblastoma.<\/strong><\/p>\n<p><strong>The\u00a0Ocular Oncology Centre of MITERA Hospital is\u00a0<u>the only Ophthalmic center\u00a0<\/u>in Greece and whole Europe with this Equipment<\/strong><\/p>\n<ul>\n<li>Take OCT to your patient: The handheld OCT scan head and mobile cart provides flexibility to image from the ICU, operating room, and clinic.<\/li>\n<li>Focus with confidence: The Envisu C2300 can be mounted on a surgical microscope for steady, high-quality live imaging.<\/li>\n<li>Get brilliant detail when you need it: High-resolution, real-time images can be seen with detail down to 3 \u03bcm.<\/li>\n<li>Explore with full volume: Featuring full 3D volumetric data capturing capability with fully customizable high density data scans up to 1000 x 1000.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/heidelberg.jpg\" \n                         alt=\"HEIDELBERG SPECTRALIS OPTICAL COHERENCE TOMOGRAPHY\"\n                         loading=\"lazy\">\n                                \n                <h3>HEIDELBERG SPECTRALIS OPTICAL COHERENCE TOMOGRAPHY<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Spectralis is a world-renowned device for fundus tomography. Heidelberg Spectralis Optical Coherence Tomography, an expandable diagnostic imaging platform wich combines...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p><strong>Spectralis is a world-renowned device for fundus tomography.<\/strong><\/p>\n<p>Heidelberg Spectralis Optical Coherence Tomography, an expandable diagnostic imaging platform wich combines scanning laser fundus imaging with high-resolution OCT imaging, and the enhanced depth imaging OCT (EDI-OCT), are helpful in the diagnosis, treatment planning and monitoring response of ocular and periocular tumours in adults and children.<\/p>\n<p>It is designed to provide high quality pictures of the retina macula, the optic nerve and other optical tissues and help to diagnose Diabetic Retinopathy, Age-related Macular Degeneration and several other pathologies.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/heidel.jpg\" \n                         alt=\"HEIDELBERG SPECTRALIS MULTI-SPECTRAL FUNDUS IMAGING (MULTICOLOUR MODULE IMAGING)\"\n                         loading=\"lazy\">\n                                \n                <h3>HEIDELBERG SPECTRALIS MULTI-SPECTRAL FUNDUS IMAGING (MULTICOLOUR MODULE IMAGING)<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Multi-spectral fundus imaging (Multicolour Module Imaging) on Heidelberg Engineering OCT Spectralis, an imaging acquired with three simultaneous laser beams at...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Multi-spectral fundus imaging (Multicolour Module Imaging) on Heidelberg Engineering OCT Spectralis, an imaging acquired with three simultaneous laser beams at different depths of the ocular fundus, a novel technique that can be used to highlight different layers within the retina simultaneously, provides three monochromatic images that can reveal topographic changes not visible with conventional color fundus photography, crucial diagnostic tool help find tumour boundaries and the extent of macular involvement, which may be useful for assessing visual impact.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/05\/10.jpg\" \n                         alt=\"HEIDELBERG SPECTRALIS FLUORESCEIN (FA) AND INDOCYANINE ANGIOGRAPHY (ICG)\"\n                         loading=\"lazy\">\n                                \n                <h3>HEIDELBERG SPECTRALIS FLUORESCEIN (FA) AND INDOCYANINE ANGIOGRAPHY (ICG)<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Fundus imaging modalities, including high-resolution images and video sequences that show vessel filling, flow and leakage and are essential tools...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Fundus imaging modalities, including high-resolution images and video sequences that show vessel filling, flow and leakage and are essential tools for the investigation of tumour circulation.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/11.jpg\" \n                         alt=\"ABSOLU ULTRASOUND WIRH IAnnular B20 MHz probe\"\n                         loading=\"lazy\">\n                                \n                <h3>ABSOLU ULTRASOUND WIRH IAnnular B20 MHz probe<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">PERMITS IMAGING EXCELLENCE The entire eye is visible with an exceptional level of detail, a crucial diagnostic element for the...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p><strong>PERMITS IMAGING EXCELLENCE<br \/>\n<\/strong> The entire eye is visible with an exceptional level of detail, a crucial diagnostic element for the diagnosis of eye tumors.<\/p>\n<p>ABSolu combines the best image quality, the highest measurement accuracy in its category, with excellent ergonomics.<\/p>\n<p>The ultrasound is the primary diagnostic test that confirms the diagnosis of choroidal melanoma as well as the size, thickness (apical height), basal dimension, extraocular extension (such as scleral nodules), and document growth during the follow-up of a suspicious nevus\/small melanoma.<\/p>\n<p>Ultrasonography in retinoblastoma patients is very helpful in accessing the tumor and in differentiating retinoblastoma from other conditions<\/p>\n<p>Innovative B-scan probe 20MHz, with five concentric rings that direct the ultrasound according to the requirements of the examination and offer 70% greater examination depth and increase the detail of the imaging by 25%.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/12.jpg\" \n                         alt=\"ABSOLU A-B-UBM ULTRASOUND &#8211; STANDARDIZED PROBE\"\n                         loading=\"lazy\">\n                                \n                <h3>ABSOLU A-B-UBM ULTRASOUND &#8211; STANDARDIZED PROBE<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">A-scan probe, standardized by Ossoinig at 8MHz Specialized A-scan probe, standardized by Ossoinig at 8MHz, ideal for clinical examination of...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p><strong>A-scan probe, standardized by Ossoinig at 8MHz<\/strong><\/p>\n<p>Specialized A-scan probe, standardized by Ossoinig at 8MHz, ideal for clinical examination of ultrasound absorption characteristics of tumors, carcinomas, melanomas and other pathological findings.<\/p>\n<p>Absolu Standardized probe, important tool on diagnosis of eye tumour<\/p>\n<p>ABSolu combines the best image quality, the highest measurement accuracy in its category, with excellent ergonomics.<\/p>\n<p>&nbsp;<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/13.jpg\" \n                         alt=\"ABSOLU A-B-UBM ULTRASOUND &#8211; UBM 50 MHZ LINEAR\"\n                         loading=\"lazy\">\n                                \n                <h3>ABSOLU A-B-UBM ULTRASOUND &#8211; UBM 50 MHZ LINEAR<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">UBM 50 MHz ultrasonic biomicroscopy probe, ideal for the detailed examination of the anterior segment of the eye (cornea, iris,...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>UBM 50 MHz ultrasonic biomicroscopy probe, ideal for the detailed examination of the anterior segment of the eye (cornea, iris, circular body) with unsurpassed resolution and tools for quantifying various sizes in the image (angle, angular opening, lens vault, etc.).<\/p>\n<p>ABSOLU Ultrasound biomicroscopy (UBM) 50MHz linear, an important tool for assessing and the management of anterior segment tumours. Selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the precise evaluation of anterior extension of the disease.<\/p>\n<p>Improved UBM technology makes it possible to diagnose structures behind the iris that other technologies cannot visualize. The new signal processing mode offers increased resolution and invasiveness.<\/p>\n<p><strong>ABSolu combines the best image quality, the highest measurement accuracy in its category, with excellent ergonomics.<\/strong><\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/14.jpg\" \n                         alt=\"ZEISS HUMPHREY FIELD ANALYZER 3\"\n                         loading=\"lazy\">\n                                \n                <h3>ZEISS HUMPHREY FIELD ANALYZER 3<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Humphrey Field Analyzer 3 combines everything that you can imagine making it simpler, faster and more reliable than ever before...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p><strong>Humphrey Field Analyzer 3 combines everything that you can imagine making it simpler, faster and more reliable than ever before in a Humphrey<\/strong><\/p>\n<p>Humphrey Visual Fields, used to detect blind spots or scotomas in the visual field. The nature of such blind spots (shape, size, depth) can point towards different disorders of the eye, optic nerve or visual pathway in the brain, including also tumours.<\/p>\n<p>Quicker, simpler, more dependable than ever Liquid Lens technologies: One lens, less time The automatic Liquid Trial Lens reduces patient setup time by automatically loading each patient correction from the previous examination.<\/p>\n<p>The improvements in HFA3 from a Humphrey add to the standard that is reliable that thousands of clinics already depend on for critical diagnoses. The new model still provides when and where you require it.<\/p>\n<p>STATPAC\u2122 statistical software provides comprehensive analysis by comparing results to proprietary age-normative and glaucoma databases, enabling effective monitoring of visual field changes over time.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/15.jpg\" \n                         alt=\"OPTOVUE VISIONIX SOLIX OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY (OCTA)\"\n                         loading=\"lazy\">\n                                \n                <h3>OPTOVUE VISIONIX SOLIX OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY (OCTA)<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">SOLIX is a new technology built upon a proven foundation of high-speed Spectral Domain OCT. This FullRange platform empowers practitioners...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>SOLIX is a new technology built upon a proven foundation of high-speed Spectral Domain OCT. This FullRange platform empowers practitioners to identify and manage numerous pathologies from the front of the eye to the back for a vastly superior diagnostic experience.<\/p>\n<p>Visionix Optical coherence tomography angiography (OCTA) is a noninvasive imaging modality used to diagnose and manage retinal and choroidal vascular disease.OCTA has the ability to detect subtle lesions that are not identifiable during clinical examinations. OCTA has a role in understanding tumour vascularity.<\/p>\n<p>SOLIX delivers multiple tools for a new generation of disease management that improve throughput and enable superior patient care:<\/p>\n<ul>\n<li>FullRange anterior segment imaging to capture the entire anterior chamber in a single scan<\/li>\n<li>External IR imaging to enable evaluation of Meibomian glands of the upper and lower lids without a dedicated imaging device<\/li>\n<li>Proven glaucoma analytics that combine structural and vascular images and measurements \u2022 FullRange retinal imaging that allows wide and deep imaging of the retina, choroid and vitreous\u2026even in highly myopic patients<\/li>\n<li>Optovue\u2019s industry-leading AngioVue\u00ae OCT Angiography (OCTA) for non-invasive 3D visualization and quantification of retinal vasculature*<\/li>\n<li>Fundus and external color photography<\/li>\n<li>Wellness capabilities that have become part of a new standard of care for patients suspected of both retinal pathologies and glaucoma<\/li>\n<li>Ultra-fast spectral-domain technology produces a wide and deep field of view that does not compromise image resolution<\/li>\n<li>Multi-volume merge averages four scan volumes to deliver high-density images with pristine clarity<\/li>\n<li>3D vessel rendering enables real-life visualization of retinal vasculature and vascular connectivity \u2022 3D PAR 2.0 rapidly removes the majority of projection artifact from the deep plexus to simplify image interpretation and produce more reliable quantification<\/li>\n<li>New segmentation algorithms dramatically improve Bruch\u2019s membrane and RPE segmentation for more confident assessment \u2013 even in highly diseased eyes<\/li>\n<li>DualTrac\u2122 Motion Correction Technology with enhanced visualization combines real-time tracking and patented postprocessing to enable true 3D correction of distortion in all directions for ultra-precise motion correction.<\/li>\n<\/ul>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/16.jpg\" \n                         alt=\"OPTOVUE VISIONIX SOLIX ANTERIOR SEGMENT OPTICAL COHERENCE TOMOGRAPHY (AS-OCT)\"\n                         loading=\"lazy\">\n                                \n                <h3>OPTOVUE VISIONIX SOLIX ANTERIOR SEGMENT OPTICAL COHERENCE TOMOGRAPHY (AS-OCT)<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">SOLIX is a new technology built upon a proven foundation of high-speed Spectral Domain OCT. This FullRange platform empowers practitioners...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>SOLIX is a new technology built upon a proven foundation of high-speed Spectral Domain OCT. This FullRange platform empowers practitioners to identify and manage numerous pathologies from the front of the eye to the back for a vastly superior diagnostic experience.<\/p>\n<p>OCT provides detailed images of ocular tissue structure, enabling early detection of anomalies and monitoring of ocular disease progression.<\/p>\n<p>AS-OCT has proved to be an indispensable diagnostic tool in diagnosing and managing conjunctival and corneal pathologies.<\/p>\n<p>AS-OCT has been widely used in the diagnosis of ocular surface tumours providing in vitro \u201coptical biopsy\u201d features that offers similar if not better results in demonstrating internal tumor features.<\/p>\n<p>SOLIX delivers multiple tools for a new generation of disease management that improve throughput and enable superior patient care:<\/p>\n<ul>\n<li>FullRange anterior segment imaging to capture the entire anterior chamber in a single scan<\/li>\n<li>External IR imaging to enable evaluation of Meibomian glands of the upper and lower lids without a dedicated imaging device<\/li>\n<li>Proven glaucoma analytics that combine structural and vascular images and measurements \u2022 FullRange retinal imaging that allows wide and deep imaging of the retina, choroid and vitreous\u2026even in highly myopic patients<\/li>\n<li>Fundus and external color photography<\/li>\n<li>Wellness capabilities that have become part of a new standard of care for patients suspected of both retinal pathologies and glaucoma<\/li>\n<li>Ultra-fast spectral-domain technology produces a wide and deep field of view that does not compromise image resolution<\/li>\n<li>Multi-volume merge averages four scan volumes to deliver high-density images with pristine clarity<\/li>\n<li>3D vessel rendering enables real-life visualization of retinal vasculature and vascular connectivity \u2022 3D PAR 2.0 rapidly removes the majority of projection artifact from the deep plexus to simplify image interpretation and produce more reliable quantification<\/li>\n<li>New segmentation algorithms dramatically improve Bruch\u2019s membrane and RPE segmentation for more confident assessment \u2013 even in highly diseased eyes<\/li>\n<li>DualTrac\u2122 Motion Correction Technology with enhanced visualization combines real-time tracking and patented postprocessing to enable true 3D correction of distortion in all directions for ultra-precise motion correction.<\/li>\n<\/ul>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/17.jpg\" \n                         alt=\"TONO-PEN AVIA\"\n                         loading=\"lazy\">\n                                \n                <h3>TONO-PEN AVIA<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Tono-Pen provides fast, accurate, and reliable IOP measurements that are less sensitive to corneal centration and can be taken in...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Tono-Pen provides fast, accurate, and reliable IOP measurements that are less sensitive to corneal centration and can be taken in any position, including on patients in beds or wheelchairs.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/18.jpg\" \n                         alt=\"HAAG-STREIT AT-900\"\n                         loading=\"lazy\">\n                                \n                <h3>HAAG-STREIT AT-900<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">The Applanation Tonometer by the Swiss Haag-Streit, is the ophthalmology golden standard for measuring the intraocular pressure. For over 50...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>The Applanation Tonometer by the Swiss Haag-Streit, is the ophthalmology golden standard for measuring the intraocular pressure. For over 50 years, ophthalmologists have been trusting its accurate measurements and millions of patients have been examined all around the world.<\/p>\n<p>The digital Goldmann tonometer AT 900 D adds the advantages of state-of-the-art digital technology with easy to read digital IOP display.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/19.jpg\" \n                         alt=\"ZEISS IOLMASTER 700\"\n                         loading=\"lazy\">\n                                \n                <h3>ZEISS IOLMASTER 700<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">The ZEISS IOLMaster 700 is a cutting-edge optical biometer that enhances cataract surgery planning through advanced Swept Source OCT technology....<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>The <strong>ZEISS IOLMaster 700<\/strong> is a cutting-edge optical biometer that enhances cataract surgery planning through advanced Swept Source OCT technology. This innovative system provides superior precision, consistency, and depth penetration for more accurate intraocular lens (IOL) calculations. Swept Source OCT enables deeper penetration into the opaque cataractous lens, capturing clear images of the retina and foveal pit.<\/p>\n<p><strong>Key Features of the IOLMaster 700:<\/strong><\/p>\n<ol>\n<li><strong>Total Keratometry (TK)<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Utilizes Swept Source OCT to measure both anterior and posterior corneal surfaces, leading to a more accurate estimation of true corneal power.<\/li>\n<li>Essential for toric IOL calculations by factoring in posterior corneal astigmatism, improving post-surgical outcomes.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><strong>Central Topography<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Provides a detailed central corneal shape analysis, crucial for detecting asymmetries.<\/li>\n<li>Helps surgeons optimize surgical planning without requiring additional corneal imaging devices.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><strong>Barrett Suite<\/strong><\/li>\n<\/ol>\n<p>The IOLMaster 700 includes the Barrett Suite, which consists of advanced formulas for more precise IOL calculations:<\/p>\n<ul>\n<li>Barrett TK Universal II \u2013 Uses Total Keratometry for more accurate IOL power predictions.<\/li>\n<li>Barrett TK Toric \u2013 Enhances toric IOL calculations by incorporating posterior corneal measurements.<\/li>\n<li>Barrett True K with TK \u2013 Designed for post-refractive surgery patients, improving accuracy by over 12% within \u00b10.5 D.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Telecentric Keratometry<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Ensures highly precise and repeatable anterior corneal curvature measurements.<\/li>\n<li>Eliminates variability caused by measurement geometry, leading to consistent data.<\/li>\n<\/ul>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/20.jpg\" \n                         alt=\"VISIONIX VX-40\"\n                         loading=\"lazy\">\n                                \n                <h3>VISIONIX VX-40<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Complete prescription analysis in 30 seconds. Visionix Wavefront technology allows us \u00a0to have a full detailed analysis of a frame...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Complete prescription analysis in 30 seconds. Visionix Wavefront technology allows us \u00a0to have a full detailed analysis of a frame at the push of the button. Experience the next generation auto lensmeter with the VX 40. The VX 40 can detect and analyze single vision, bifocals, and progressive lenses and is compatible with all lens technologies and brands.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/21.jpg\" \n                         alt=\"VISIONIX VX-65\"\n                         loading=\"lazy\">\n                                \n                <h3>VISIONIX VX-65<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">An essential phoropter you can rely on. The new and modern automatic phoropter VX65, from Visionix, achieves precise measurements and...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>An essential phoropter you can rely on. The new and modern automatic phoropter VX65, from Visionix, achieves precise measurements and ergonomics, at high speed! Designed to withstand the passage of time, thanks to its high quality and technologically advanced construction materials, it is one of the most reliable optometric tools on the market. It can be combined with the rest of Visionix optometric equipment, for communication between the machines and immediate transfer of results from one to another, offering you speed of work.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/22.jpg\" \n                         alt=\"VISIONIX VX-90\"\n                         loading=\"lazy\">\n                                \n                <h3>VISIONIX VX-90<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">The Visionix VX 90 is an ophthalmic diagnostic device with refraction and keratometry functionalities as well as accurate of cataracts....<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>The Visionix VX 90 is an ophthalmic diagnostic device with refraction and keratometry functionalities as well as accurate of cataracts. A moving fixation target with auto fogging allows the patient to fully desaccommodate in order to get the patient refraction in any conditions.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/23.jpg\" \n                         alt=\"CSO FUTURE DELUXE 2_3\"\n                         loading=\"lazy\">\n                                \n                <h3>CSO FUTURE DELUXE 2_3<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">It is a robust 3 instrument unit with electric movement of each instrument. The unit is equipped with a drawer...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>It is a robust 3 instrument unit with electric movement of each instrument. The unit is equipped with a drawer for storing the tonometer and a ceiling light, with three LED lights. It has two new generation touch panels, with backlight, easy to use and clean. On the panels, there are all the main commands and it is also possible to memorize all the functions of the unit for easy and comfortable daily use.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/24.jpg\" \n                         alt=\"LUNEAU\"\n                         loading=\"lazy\">\n                                \n                <h3>LUNEAU<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">The retractable Aesthesiometer with a 12\/100 mm nylon thread for measuring the tactile sensitivity of the Cornea and eyelid margin....<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>The retractable Aesthesiometer with a 12\/100 mm nylon thread for measuring the tactile sensitivity of the Cornea and eyelid margin.<\/p>\n<p>Provides direct reading on the instrument of the length of the very precisely calibrated filament, based upon the principle of pressure transmitted axially by a nylon monofilament, of known diameter but of variable length, for a given bending stress. Examination of corneal sensitivity in tumors, such as acoustic neuroma or angioma.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/25.jpg\" \n                         alt=\"KEELER PROFESSIONAL\"\n                         loading=\"lazy\">\n                                \n                <h3>KEELER PROFESSIONAL<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">The Professional Ophthalmoscope has been designed to ensure ultimate control. Lenses, graticules and filters can all be introduced at the...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>The Professional Ophthalmoscope has been designed to ensure ultimate control. Lenses, graticules and filters can all be introduced at the touch of a fingertip without the need to pull away from the patient.<\/p>\n<p>Positive action maywheel and comprehensive lens range The positive action, easy access, maywheel not only allows you to dial up the required lens quickly, but also gives you total control of where you are in the lens range making each exam quicker and easier.<\/p>\n<p>The extensive range of +29D to \u201330D in single dioptre steps ensures easy examination of all ocular structures and covers a wide range of patient\/user prescriptions. A quick step swing of +\/- 20D helps speed up diagnosis.<\/p>\n<p>Xenon illumination The Professional also uses Xenon illumination for a brighter and whiter long lasting light. Giving you more power and fewer bulb changes.<\/p>\n<p><strong>Swing over filter\u00a0 <\/strong>The red free filter for enhanced vessel examination can be used in conjunction with any of the 6 diagnostic beams.<\/p>\n<p><strong>Brow rest\u00a0\u00a0<\/strong>The integral soft brow rest allows for easy positioning and protects your lenses if you are a spectacle wearer.<\/p>\n<p>With the additional glaucoma spot system, it provides improved diagnostic capabilities. They accept a rechargeable lithium battery.<\/p>\n<p>An excellent optical system.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/26.jpg\" \n                         alt=\"KEELER PROFESSIONAL COMBI RETINOSCOPE\"\n                         loading=\"lazy\">\n                                \n                <h3>KEELER PROFESSIONAL COMBI RETINOSCOPE<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Optimized for outstanding performance with either a Streak or Spot halogen beam with a simple bulb change.\u00a0New LED Retinoscope guarantees...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Optimized for outstanding performance with either a Streak or Spot halogen beam with a simple bulb change.\u00a0New LED Retinoscope guarantees enough light to refract even the most difficult eyes. The only Retinoscope allowing rapid confirmation of neutralization.<\/p>\n<p>Change of the beam from divergent to convergent enabling to cross check the accuracy of the neutral point, guaranteeing the assessment is correct every time.<\/p>\n<p>Improved 360\u00ba access to a single control for both rotation and convergence adjustments. The precision movements are achieved by use of rare earth magnet technology.<\/p>\n<p>A simple finger movement allows a choice of 4 mm or 1.7 mm aperture to optimize brightness or resolution of the retinal reflex.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/27.jpg\" \n                         alt=\"KEELER VANTAGE PLUS\"\n                         loading=\"lazy\">\n                                \n                <h3>KEELER VANTAGE PLUS<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Vantage PLUS LED Ophthalmoscope for imaging in examination room, operating room, or anywhere else. ADVANTAGES: LED light source, which provides...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Vantage PLUS LED Ophthalmoscope for imaging in examination room, operating room, or anywhere else.<\/p>\n<p><strong>ADVANTAGES:<\/strong><\/p>\n<ul>\n<li>LED light source, which provides white lighting with long battery life and no need to buy bulbs. The lifespan of the LED source reaches 10,000 hours.<\/li>\n<li>Clinically, superior optical systems combined with LED lighting can provide more detail, allowing the detection of retinal pathology<\/li>\n<\/ul>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/28.jpg\" \n                         alt=\"KEELER VANTAGE-PLUS DIGITAL\"\n                         loading=\"lazy\">\n                                \n                <h3>KEELER VANTAGE-PLUS DIGITAL<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Vantage Plus LED Digital Ophthalmoscope for digital imaging in examination room, operating room, or anywhere else. As the world leader...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Vantage Plus LED Digital Ophthalmoscope for digital imaging in examination room, operating room, or anywhere else. As the world leader in binocular indirect technology we lead the way again with the first digital binocular indirect system. Not old analog video but true digital imaging.\u00a0<strong>The Ocular Oncology Centre of MITERA Hospital is\u00a0<\/strong><strong><u>The only Ophthalmic center\u00a0<\/u><\/strong><strong>in Greece with this Equipment.<\/strong><\/p>\n<p>Plugs into PC to record examinations in digital format.<\/p>\n<p>Keeler Software\u00a0for easy still or dynamic imaging, storage and documentation.<\/p>\n<p>Vantage Plus LED Slimline Wireless. Built on the number one selling LED and wireless slimline system.<\/p>\n<p>&nbsp;<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/29.jpg\" \n                         alt=\"KEELER Cryomatic MK II\"\n                         loading=\"lazy\">\n                                \n                <h3>KEELER Cryomatic MK II<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Keeler Cryomatic MKII Cryo Console using a small metal probe that is cooled to very low temperatures, killing the cancer...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Keeler Cryomatic MKII Cryo Console using a small metal probe that is cooled to very low temperatures, killing the cancer cells by freezing them.<\/p>\n<p>Cryotherapy can be used as primary or adjunctive\/combined therapy in retinoblastoma patients and in several types of ocular tumours in adults.<\/p>\n<p>The Cryomatic MK II delivers quality and versatility when using either disposable or reusable probes.<\/p>\n<p>The Cryomatic MK II\u2019s new coupling system allows you to connect either a single use disposable or reusable probe without the need for an adaptor. The new integral software automatically detects the type of probe in use and adjusts the unit accordingly, meaning the unit is ready for use in a matter of minutes.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/30.jpg\" \n                         alt=\"IRIDEX GREEN IQ 532 LASER\"\n                         loading=\"lazy\">\n                                \n                <h3>IRIDEX GREEN IQ 532 LASER<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">The innovative IQ 532 model from Iridex is a green laser that features the unique Micropulse\u00ae technology. The IQ 532...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>The innovative IQ 532 model from Iridex is a green laser that features the unique Micropulse\u00ae technology. The IQ 532 emits a green laser beam at 532 nm, is solid-state and is a multipurpose laser since it can be used as a repeatable treatment for glaucoma, with micropulse laser trabeculoplasty (MLT) but also for macular diseases, such as age-related macular degeneration, diabetic macular edema, productive diabetic retinopathy, retinal tears and many more applications.<\/p>\n<p>The iRIDEX Patent Micropulse Laser Treatment Laser photocoagulation could be used to ablate the ischemic zone after radiotherapy in patients with choroidal melanoma, regressing radiation retinopathy and destroy radiation-induced retinal ischemia to treat, prevent or delay radiation-induced maculopathy<\/p>\n<p>It is available in 2 versions, with or without Micropulse\u00ae and can be connected to a variety of slit lamps, with an indirect ophthalmoscope (LIO) or used in surgery with an endolaser probe.<\/p>\n<p>Very important is the fact that the Laser can be upgraded to a Pattern Laser (multi-target) by connecting to the TX Cell system.<\/p>\n<p><strong>PRODUCT HIGHLIGHTS\u00a0<\/strong><\/p>\n<ul>\n<li>High power for greater range of therapy alternatives<\/li>\n<li>Dual port for efficient setup of alternate delivery devices<\/li>\n<li>Repeatable laser sessions for retinal diseases with optional MicroPulse module<\/li>\n<\/ul>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/31.jpg\" \n                         alt=\"IRIDEX SLIT LAMP DIODE LASER OCULIGHT SLX 810NM\"\n                         loading=\"lazy\">\n                                \n                <h3>IRIDEX SLIT LAMP DIODE LASER OCULIGHT SLX 810NM<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Semiconductor diode lasers that deliver true continuous wave infrared laser (810 nm) light for ophthalmic applications. Transpupillary Thermotherapy treatment with...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Semiconductor diode lasers that deliver true continuous wave infrared laser (810 nm) light for ophthalmic applications.<\/p>\n<p>Transpupillary Thermotherapy treatment with the possibility of large and small spots (also called Diode Laser Hyperthermia treatment)<\/p>\n<p>Diode laser transpupillary thermotherapy (TTT) effectively treats retinal and choroidal diseases, such as choroidal hemangioma and choroidal melanoma, as a beam of light shrinks or destroys cancer cells and is also effective in treating tumor-related neovascular glaucoma<\/p>\n<p><strong>The Ocular Oncology Centre of MITERA Hospital is The only Ophthalmic center in Greece proving this treatment. <\/strong><\/p>\n<p>The Industry Standard for High-Performance Versatility. The OcuLight \u00ae SLx 810 nm infrared laser offers high performance for retinal\u00a0photocoagulation and glaucoma procedures, including transscleral applications.<\/p>\n<p>The versatile capability of the OcuLight SLx system offers three different laser energy delivery modalities: CW-Pulse\u2122, MicroPulse\u2122, and LongPulse\u2122. The system\u2019s highly ergonomic user\u00a0interface, infrared wavelength, and wide choice of delivery systems offer a broad spectrum of treatment options particularly well suited for retinopathy of prematurity and end-stage glaucoma.<\/p>\n<p>&nbsp;<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/32.jpg\" \n                         alt=\"IRIDEX LASER INDIRECT OPTHALMOSCOPE PLUS\"\n                         loading=\"lazy\">\n                                \n                <h3>IRIDEX LASER INDIRECT OPTHALMOSCOPE PLUS<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">The Iridex Laser Indirect Ophthalmoscope Plus is an easy-to-use Laser indirect ophthalmoscope that is ergonomic and provides excellent imaging and...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>The Iridex Laser Indirect Ophthalmoscope Plus is an easy-to-use Laser indirect ophthalmoscope that is ergonomic and provides excellent imaging and treatment flexibility with reliability. It is considered the gold standard of indirect ophthalmoscopes and in combination with the Diode Laser Oculight SLX is used for the effective treatment of intraocular tumors.<\/p>\n<p>The treatment works by slowly raising the temperature of the tumor.<\/p>\n<p>The laser delivers low-level heat to the area, killing the cancer cells and shrinking the tumour. This laser uses infrared light to target the tumor, effectively heating and destroying the cancer cells.<\/p>\n<p>Transpupillary thermotherapy (TTT) is one of the treatment options for Retinoblastoma patients. It can be used alone or in combination with other treatments.<\/p>\n<p><strong>The Ocular Oncology Centre of MITERA Hospital is\u00a0<\/strong><strong><u>The only Ophthalmic center\u00a0<\/u><\/strong><strong>in Greece with this Equipment\u00a0<\/strong><\/p>\n<p>It enables the delivery of laser energy to the most distant periphery of the retina, as well as the ability to treat patients in a supine position.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/33.jpg\" \n                         alt=\"IRIDEX TRUFOCUS LASER INDIRECT OPHTHALMOSCOPE PREMIERE\"\n                         loading=\"lazy\">\n                                \n                <h3>IRIDEX TRUFOCUS LASER INDIRECT OPHTHALMOSCOPE PREMIERE<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">Green laser delivered via an indirect ophthalmoscope system Indirect Ophthalmoscope (LIO) Premiere is an optical system projects an aiming and...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>Green laser delivered via an indirect ophthalmoscope system<\/p>\n<p>Indirect Ophthalmoscope (LIO) Premiere is an optical system projects an aiming and treatment laser beam delivered from the laser via a fiber optic cable. The laser focuses on the blood vessels surrounding and supplying the tumour, destroying them by heating them.<\/p>\n<p>Used alone or combined with other treatments is effective in the treatment of retinoblastoma and in other ocular tumours.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/34.jpg\" \n                         alt=\"IRIDEX TXCell Scanning Laser Delivery System Slit Lamp Adapter\"\n                         loading=\"lazy\">\n                                \n                <h3>IRIDEX TXCell Scanning Laser Delivery System Slit Lamp Adapter<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">The TXCell Scanning Laser Delivery System, from the American company Iridex, is a multi-point pattern scanning device that connects to...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>The TXCell Scanning Laser Delivery System, from the American company Iridex, is a multi-point pattern scanning device that connects to the IQ 532 or IQ 577.<\/p>\n<p>The TxCell Scanning coupled to the Iridex IQ 532\u00ae or IQ 577\u00ae adds multiple treatment modalities for glaucoma and retinal disorders.<\/p>\n<p>It is a versatile platform for advanced retinal treatment, allowing for multi-point pattern scanning for effective photocoagulation of the retina, with or without MicroPulse\u2122.<\/p>\n<p>With its high-speed pulse capability, it offers increased treatment speed and improved precision in the placement of laser spots, which is crucial for the patient, for you, and for more effective treatment<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/35.jpg\" \n                         alt=\"IRIDEX OPERATING MICROSCOPE ADAPTER\"\n                         loading=\"lazy\">\n                                \n                <h3>IRIDEX OPERATING MICROSCOPE ADAPTER<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">This is a unique treatment system with a diode laser for patients in a recumbent position. The device connects to...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>This is a unique treatment system with a diode laser for patients in a recumbent position. The device connects to the surgical microscope and allows for the application of the diode laser over extended periods.<\/p>\n<p>Adds the therapeutic capability of retinal photocoagulation to an operating microscope.<\/p>\n<p>It is ideal for the treatment of retinoblastoma and in other ocular tumours.<\/p>\n                <\/div>\n            <\/div>\n                        <div class=\"exoplismos-item\">\n                                    <img decoding=\"async\" src=\"https:\/\/www.mitera.gr\/wp-content\/uploads\/2025\/06\/36.jpg\" \n                         alt=\"IRIDEX SLIT LAMP ADAPTERS\"\n                         loading=\"lazy\">\n                                \n                <h3>IRIDEX SLIT LAMP ADAPTERS<\/h3>\n                \n                                    <p class=\"exoplismos-intro\">We have Slit Lamp adapters for Ocular Oncology Center\u2019s lasers. These adapters provide precise focusing and uniform energy density, featuring...<\/p>\n                                \n                <button class=\"exoplismos-toggle\" \n                        data-more-text=\"MORE\"\n                        data-less-text=\"LESS\">\n                    MORE                <\/button>\n                \n                <div class=\"exoplismos-content\">\n                    <p>We have Slit Lamp adapters for Ocular Oncology Center\u2019s lasers. These adapters provide precise focusing and uniform energy density, featuring unparalleled optics, accuracy, and ease of use in various spot sizes. They are durable, ergonomic, and have a metal design for easy installation and long-term reliability.<\/p>\n<p>Improved optics promote superior viewing of target tissue during treatment and maximum resolution, delivery, and color balance \u00b0 50\u2013500 \u00b5m spot sizes \u00b0 Includes micromanipulator for precise laser positioning<\/p>\n<p>600-5000 \u00b5m spot sizes available with large spot adapters &#8211; Larger Spot available for Transpupillary Thermotherapy (TTT)<\/p>\n                <\/div>\n            <\/div>\n            <\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"class_list":["post-28156","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1 - Mitera<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mitera.gr\/en\/exoplismos\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1 - Mitera\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mitera.gr\/en\/exoplismos\/\" \/>\n<meta property=\"og:site_name\" content=\"Mitera\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-26T19:02:57+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/exoplismos\\\/\",\"url\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/exoplismos\\\/\",\"name\":\"\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1 - Mitera\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/#website\"},\"datePublished\":\"2025-05-06T08:46:07+00:00\",\"dateModified\":\"2025-06-26T19:02:57+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/exoplismos\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.mitera.gr\\\/en\\\/exoplismos\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/exoplismos\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u0391\u03c1\u03c7\u03b9\u03ba\u03ae \u03c3\u03b5\u03bb\u03af\u03b4\u03b1\",\"item\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/\",\"name\":\"Mitera\",\"description\":\"Mitera\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.mitera.gr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1 - Mitera","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mitera.gr\/en\/exoplismos\/","og_locale":"en_US","og_type":"article","og_title":"\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1 - Mitera","og_url":"https:\/\/www.mitera.gr\/en\/exoplismos\/","og_site_name":"Mitera","article_modified_time":"2025-06-26T19:02:57+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.mitera.gr\/en\/exoplismos\/","url":"https:\/\/www.mitera.gr\/en\/exoplismos\/","name":"\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1 - Mitera","isPartOf":{"@id":"https:\/\/www.mitera.gr\/en\/#website"},"datePublished":"2025-05-06T08:46:07+00:00","dateModified":"2025-06-26T19:02:57+00:00","breadcrumb":{"@id":"https:\/\/www.mitera.gr\/en\/exoplismos\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mitera.gr\/en\/exoplismos\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.mitera.gr\/en\/exoplismos\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0391\u03c1\u03c7\u03b9\u03ba\u03ae \u03c3\u03b5\u03bb\u03af\u03b4\u03b1","item":"https:\/\/www.mitera.gr\/en\/"},{"@type":"ListItem","position":2,"name":"\u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u0391\u03b3\u03b3\u03bb\u03b9\u03ba\u03b1"}]},{"@type":"WebSite","@id":"https:\/\/www.mitera.gr\/en\/#website","url":"https:\/\/www.mitera.gr\/en\/","name":"Mitera","description":"Mitera","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mitera.gr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.mitera.gr\/en\/wp-json\/wp\/v2\/pages\/28156","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mitera.gr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mitera.gr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mitera.gr\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mitera.gr\/en\/wp-json\/wp\/v2\/comments?post=28156"}],"version-history":[{"count":0,"href":"https:\/\/www.mitera.gr\/en\/wp-json\/wp\/v2\/pages\/28156\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.mitera.gr\/en\/wp-json\/wp\/v2\/media?parent=28156"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}